• Shenzhen Veikong Electric Co., Ltd.
    Tayfun from Turkey
    Veikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
  • Shenzhen Veikong Electric Co., Ltd.
    Cristian from Chile
    It’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
  • Shenzhen Veikong Electric Co., Ltd.
    Brahim assad from Syria
    VEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Contact Person : Terry
Phone Number : 008613923736332
WhatsApp : +8613923736332
18kw 22kw 30kw 37kw 400V AC Line Reactor For vfd Induction Motor
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VKS
Minimum Order Quantity 1
Price Negotiable
Packaging Details Carton
Delivery Time 3 days, depend on the order quantity
Payment Terms Western Union, T/T, L/C, D/A, D/P, PayPal
Supply Ability 15000pcs per Month
Product Details
Product Name Ac Reactor For Motor Output Type Triple
Input Voltage 380V Output Power 2.2kw - 160KW
Application Induction Motor,water Supply Color Red
High Light

37kw AC Line Reactor

,

30kw AC Line Reactor

,

22kw vfd line reactor

Product Description

AC choke 18kw 22kw 30kw 37kw 400V AC output reactor for ac motor

 

Description of Load Reactor:

Our inverter reactors are made by H class copper wires . Reactors have the features of high linearity, high over-load capability, high voltage dip and low losses. Vacuum impregnation by special resin material provides better insulation function, high voltage stress, low noise and long lifetime. The number and position of air gaps are selected in order to minimize losses in magnetic core and windings. Limbs, yokes and air gaps are blocked by adhesives and pressing elements designed to reduce acoustic noise. The reactors are designed with natural air cooling.

 

1. High efficiency:
The battery with the same capacitance, higher efficiency, longer use time. Reliable inverter use the most advanced technology to raise the efficiency to 90%, save more energy, more environmental protection.

2. Protection systems:
Thermal protection, Overload protection, Over Voltage protection, Under Voltage protection, Low Voltage protection alarm. Inverter comes with an LED light to indicate the problem.


 

Characteristic of this series:

1. Rated Operation Power: 3/380V/50Hz or 660V/50Hz
2. Rated Operating Current: 3A to 2000A@40ºC
3. Reactive Strength: Core-Winding 3000VAC/50Hz/10mA/10S Free of arcing breaking(tested in factory)
4. Insulation Resistance: 1000VDC, insulation resistance>=100MΩ
5. Reactor'S noise is less than 65dB(to be measured at the point 1 meter away from the reactor horizontally)
6. Protection class: IP00
7. Insulation class: Above F
8. Standard IEC289, 1987 Reactor, GB10229-88 Reactor(equivalent to IEC289:1987) jb9644-1999 for semi-Conductor transmission
9. Interphase voltage is unbalanced>1.8% of rated voltage
10. Large quantity of inverter mounted on the same power line but have to minimize line current
11. Power factor calibrating capacitor or power factor correcting unit applied

 

According to the frequency of the equipment or the carrier wave height, the appropriate magnetic material is selected, and the insulation system selects the composite material of grade F or above, so that the reactor can maintain good performance even in the harsh working environment. The vacuum impregnation process and the design of low flux density make the reactor less noise and better linearity.

Application of Load Reactor:

It is recommended to use input reactors in the following circumstances:
1. frequency converters in parallel close connection.
2. line power supply has obvious disturbance from other devices (interference, over voltage).
3. there is voltage imbalance between the phases of the line power supply, exceeding 1.8% of the rated voltage.
4. a large number of converters are installed on the same line.
5. reduce cos C overload on the correction capacitor if there is a power factor correction device in the device.
6. power supply capacity is 60KVA and above, and frequency converter installation location is within 10M of large capacity power supply.
7. the frequency converter is powered by a very low impedance line (10 times higher than the inverter's rated value).

 

Product Parameters

 

Voltage Range

DC500V-1000V

Dielectric Strength

Core-Winding, AC 3000V/50Hz/5mA, free of damage in 60s

Insulation Resistance

Core-Winding, DC 1000V, Resistance > 100M ohm

Reactor's noise

less than 65dB(to be measured at the point 1 meter away from the reactor horizontally)

Standard

GB 19212.1-2008 GB/T 1094.6-2011

 

18kw 22kw 30kw 37kw 400V AC Line Reactor For vfd Induction Motor 0

 

Product Size

 

18kw 22kw 30kw 37kw 400V AC Line Reactor For vfd Induction Motor 118kw 22kw 30kw 37kw 400V AC Line Reactor For vfd Induction Motor 218kw 22kw 30kw 37kw 400V AC Line Reactor For vfd Induction Motor 3

18kw 22kw 30kw 37kw 400V AC Line Reactor For vfd Induction Motor 4

 

Leave a Message