Tayfun from TurkeyVeikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
-
Cristian from ChileIt’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
-
Brahim assad from SyriaVEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Product Name | 5.5kw To 500kw Soft Starter | Voltage | 220v/380v |
---|---|---|---|
Output Frequency | 50/60Hz | Application | Fan,pump,mixer |
Protection | Overload,over Heat,over Temperature | Power | 5.5KW-500KW |
High Light | 500kw AC Motor Soft Starter,5.5kw AC Motor Soft Starter,500kw pump soft starter |
380v 5.5kw to 500kw 50/60Hz online soft starter for ac motor
Key Feature
1, Six group parameters convenient in one soft starter to different power motors load.
2, Dynamic fault recording function and Inspecting motor feedback to realize closed loop control to give best motor start up in different conditions and different loads.
3, A variety of ways starting:voltage RAMP starting way can get the maximum output torque;Current limiting can realize biggest Limitations of the Start soft starting current.
4, Reliable quality Assurance:using computer simulation design;SMT Production process;Electromagnetic Compatibility Excellent.
Performance;High temperature aging,Vibration Test before delivery of the machine.
More control methods
VEIKONG S6000 soft starter with 6 kinds of start-up mode, 12 kinds of protection, two parking.
To MCU as the core, the use of intelligent digital control for a variety of load squirrel-cage induction motor start; allows the motor under any conditions can be smooth start, a good protection of the drag system, reducing the starting current on Power grid impact, to ensure reliable start of the motor: smooth deceleration stop, drag the system to eliminate the reaction of inertia: a complete system protection, extend system life, reduce system cost, improve system reliability: compatible with all start The various functions of the device, is the traditional star triangle, since the anti-pressure relief
Technical characteristics
Six kinds of starting parameters are available to facilitate a motor soft starter to start different power of the motor load;
Dynamic fault memory function, easy to find the cause of the malfunction;
Over-current, three-phase current imbalance, overheating, lack of phase, motor overload and other comprehensive motor integrated protection;
Powerful software features, rich hardware configuration, easy to meet the changing needs of various industries;
Profibus / Modbus two communication protocols to choose from; Compact structure design, easy to install, easy to use;
User-friendly mode of operation, the display interface can be flexibly selected: LED or LCD display. Make the operation handy;
Menu tree grouped by function for easy operation.
Technical Specification
Item |
Description |
||
Input Power Supply |
Input Voltage |
Three-phase 380V/480V/660 AC |
|
Frequency |
50/60Hz |
||
Adaptive Motor |
Squirrel-cage three-phase asynchronous motor |
||
Starting Times |
It is recommended not to exceed 20 times per hour. |
||
Control Mode |
(1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. |
||
Start Mode |
(1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. |
||
Stop Mode |
(1) Soft stop. (2) Free stop. |
||
Protective Function |
(1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14) Incorrect wiring protection of external control stop terminals. |
||
Ambient |
Place to be used |
Indoor location with good ventilation free from corrosive gas and conductive dust. |
|
Altitude |
Below 1000M. It have to rise the rate power when the altitude is more than 1000M. |
||
Temperature |
-20 +45 C |
||
Humidity |
90%RH without dew condensation. |
||
Vibration |
<0.5G |
||
Structure |
Protection Class |
IP20 |
|
Cooling Pattern |
Fans cooling. |
Product Application