Product Name | 30KW 37KW 45KW 55KW 75KW 90KW Bypass Soft Starter | Output Frequency | 50/60Hz |
---|---|---|---|
Application | Fan,pump,mixer | Protection | Overload,over Heat,over Temperature |
Output Current | 11A | Warranty | 18 Months |
Color | White And Dark Gray | Soft Starter Model | Online Soft Starter |
OEM Cabinet | Support High Protection Level OEM Cabinet | Function | Soft Starter And Energy Saving |
High Light | 75kw Fan Motor Starter,11A 75kw Soft Starter,VEIKONG 75kw Soft Starter |
30KW 37KW 45KW 55KW 75KW 90KW Bypass Soft Starter With 24 Months Warranty
Product feature
VKS-8000 is a highly intelligent, very reliable and easy to use soft starter. The newly designed functions of VKS-8000 are used for quick setting or more personalized control.
It's a perfect solution. Its performance includes:
Large LCD screen that can display feedback information in Chinese and English languages, other languages can be customized.
Remotely installable operation panel.
Intuitive programming.
Advanced start and stop control functions.
A series of motor protection functions.
Extensive performance monitoring and event logging.
Technical Specification
Item | Description | ||
Input Power Supply | Input Voltage | Three-phase 380V/480V/660 AC | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | (1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. | ||
Start Mode | (1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | (1) Soft stop. (2) Free stop. | ||
Protective Function | (1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14) Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 1000M. It have to rise the rate power when the altitude is more than 1000M. | ||
Temperature | -20 +45 C | ||
Humidity | 90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Fans cooling. |