-
Tayfun from TurkeyVeikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
-
Cristian from ChileIt’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
-
Brahim assad from SyriaVEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Place of Origin | China |
---|---|
Brand Name | VEIKONG |
Certification | CE |
Model Number | VFD500 |
Minimum Order Quantity | 1 |
Price | Negotiable |
Packaging Details | Carton and Wooden Box |
Delivery Time | 3 days, depend on the order quantity |
Payment Terms | Western Union, T/T, L/C, D/A, D/P, PayPal |
Supply Ability | 15000pcs per Month |
Product Name | 220KW 250KW 280KW 315KW 350KW VFD | Display | LED/LCD |
---|---|---|---|
Voltage | 380V-480V | Warranty | 18 Months |
Communication | RS485、Profinet | PG Card | Support Different Type PG Card |
High Light | 350KW Variable Frequency Drive Inverter,220KW China Frequency Inverter,315KW Motor Frequency Inverter |
220KW 250KW 280KW 315KW 350KW Variable Frequency Drive Inverter
220KW 250KW 280KW 315KW 350KW VFD Variable Frequency Inverter For Textile Machinery
Product Feature
1. VF and Sensorless Vector Control
2. Up to 0Hz/200% starting torque
3. Built-in braking unit (≤30kW), Optional external braking unit (≥37kW)
4. External LED keypad to copy parameters(≥18.5kW), Standard membrane keypad design(≤15kW), Optional LCD keypad provided
5. Standard C3 filters; Optional C2 filters
6. Accurate parameters auto tuning and better motor drive
7. Simple water supply function
8. Support G/P dual rating
9. Customization services provided (like PTC )
10. CE requirements certified
Technical Specification
Item | Specification | |
Input | Input Voltage |
1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
Allowed Voltage fluctuation range | -15%~10% | |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
Output | Output Voltage | 3phase:0~input voltage |
Overload capacity |
General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current |
|
Control | Control mode |
V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) |
Operating mode | Speed control,Torque control(SVC and VC) | |
Speed range |
1:100 (V/f) 1:200( SVC) 1:1000 (VC) |
|
Speed control accuracy |
±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) |
|
Speed response |
5Hz(V/f) 20Hz(SVC) 50Hz(VC) |
|
Frequency range |
0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
|
Input frequency resolution |
Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% |
|
Startup torque |
150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) |
|
Torque control accuracy |
SVC:within 5Hz10%,above 5Hz5% VC:3.0% |
|
V/f curve |
V / f curve type: straight line, multi point, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost |
|
Frequency giving ramp |
Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s |
|
DC bus voltage control |
Over-voltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;
Under-voltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure
VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; Vdc Min control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump under-voltage fault |
|
Carrier frequency | 1kHz~12kHz(Varies depending on the type) | |
Startup method | Direct start (can be superimposed DC brake); speed tracking start | |
Stop method | Deceleration stop (can be superimposed DC braking); free to stop | |
Main control function | Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN | |
Function | Keypad | LED Digital keyboard and LCD keypad(option) |
Communication |
Standard: MODBUS communication CAN OPEN AND PROFINET( IN DEVELOPMENT) |
|
PG card | Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card | |
Input terminal |
Standard: 5 digital input terminals, one of which supports high-speed pulse input up to 50kHz; 2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input; Option card: 4 digital input terminals 2 analog input terminals.support-10V-+10V voltage input |
|
Output terminal |
standard: 1 digital output terminal; 1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output; 1 relay output terminal(second relay is an option ) 2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output; Option card: 4 digital output terminals |
|
Protection | Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function | |
Environment | Installation location | Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | 0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m | |
Ambient temperature | -10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9 m/s2 (0.6 g) | |
Storage temperature | -20°C ~ +60°C | |
Others | Installation | Wall-mounted, floor-controlled cabinet, transmural |
Protection level | IP20 | |
cooling method | Forced air cooling | |
EMC | CE ROHS |
Internal EMC filter Complies with EN61800-3 Category C3 3rd Environment |
Product Application