• Shenzhen Veikong Electric Co., Ltd.
    Tayfun from Turkey
    Veikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
  • Shenzhen Veikong Electric Co., Ltd.
    Cristian from Chile
    It’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
  • Shenzhen Veikong Electric Co., Ltd.
    Brahim assad from Syria
    VEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Contact Person : Terry
Phone Number : 008613923736332
WhatsApp : +8613923736332
22KW 30KW 37KW 45KW VFD Variable Frequency Drive 3 Phase Vector Control
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VFD500
Minimum Order Quantity 1
Price Negotiable
Packaging Details Carton and Wooden Box
Delivery Time 3 days, depend on the order quantity
Payment Terms Western Union, T/T, L/C, D/A, D/P, PayPal
Supply Ability 15000pcs per Month
Product Details
Product Name 22KW 30KW 37KW 45KW VFD Voltage 220V, 380V, 440V, 480V
Control Mode Vector Control Power Range 0.75KW-710KW
Current Depend On Model Keyboard LED And LCD
High Light

Vector Control VFD Variable Frequency Drive

,

37KW VFD Variable Frequency Drive

,

VFD 3 Phase Frequency Inverter

Product Description

22KW 30KW 37KW 45KW VFD Variable Frequency Drive 3 Phase Vector Control

 

22KW 30KW 37KW 45KW VFD Frequency Inverter 3 Phase Support Spanish Russian

 

Product Features of Three Phase VFD

Tension control and torque mode control

Up to 200% starting torque at Ohz
Asynchronous motor control
Comparator and logic unit/controller

Sleeping function

Virtual DI function

Programmable delay unit
Motor Auto-tune (static and dynamic)
2 motor parameter groups
DC Injection brakingLCD keypad and shuttle keypad optional
Integral brake chopper (<30kW)
DC reacotor 18.5KW & above optional
2 PID Control optional
Energy saving function
Modbus RTU/RS485 built in
PC Tool Software
CANopen card optional
Profinet card optional
More compact to save space
Independent dust design

IO exentsional card

Multiple PG card

 

Technical Specifications of 3 Phase VFD

 

Item

Specification

Input

Input Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range

-15%~10%

Input frequency

50Hz / 60Hz,fluctuation less than 5%

Output

Output Voltage

3phase:0~input voltage

Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

Control

Control mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating mode

Speed control,Torque control(SVC and VC)

Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

Frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multi point, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Over-voltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Under-voltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

Vdc Min control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump under-voltage fault

Carrier frequency

1kHz~12kHz(Varies depending on the type)

Startup method

Direct start (can be superimposed DC brake); speed tracking start

Stop method

Deceleration stop (can be superimposed DC braking); free to stop

Main control function

Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN

Function

Keypad

LED Digital keyboard and LCD keypad(option)

Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG card

Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card

Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

Protection

Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function

Environment

Installation location

Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

Altitude

0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m

Ambient temperature

-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C

Humidity

Less than 95%RH, without condensing

Vibration

Less than 5.9 m/s2 (0.6 g)

Storage temperature

-20°C ~ +60°C

Others

Installation

Wall-mounted, floor-controlled cabinet, transmural

Protection level

IP20

cooling method

Forced air cooling

EMC

CE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment

 

22KW 30KW 37KW 45KW VFD Variable Frequency Drive 3 Phase Vector Control 0

 

Product Application

 

22KW 30KW 37KW 45KW VFD Variable Frequency Drive 3 Phase Vector Control 1

 

22KW 30KW 37KW 45KW VFD Variable Frequency Drive 3 Phase Vector Control 2

 

 

FAQ:

 

1. What voltage range can you support?

 

Single-phase 220v input, single-phase 220v output;
Single-phase 220v input, three-phase 220v output;
Three-phase 220v input, three-phase 220v output;
Single-phase 220v input, three-phase 380v output;

 

2. What is the standard of package?

 

Below 37kw, it's carton package; 45kw and above, it's wooden package.

 

3. Do you accept OEM business?

 

We accept OEM and ODM with your autherization.

Leave a Message