Vector Control VFD AC Drive 185KW 200KW 220KW Frequency 440V
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VFD500
Minimum Order Quantity 1
Price Negotiable
Packaging Details Carton and Wooden Box
Delivery Time 3 days, depend on the order quantity
Payment Terms Western Union, T/T, L/C, D/A, D/P, PayPal
Supply Ability 15000pcs per Month
Product Details
Product Name 185KW 200KW 220KW Frequency VFD Voltage 380V, 440V, 480V
Power Range 0.75KW-710KW Keyboard LED/LCD
Type AC-DC-AC Warranty 18 Months
High Light

Vector Control VFD AC Drive

,

185KW VFD AC Drive

,

440V VFD Frequency Drive

Product Description

185KW 200KW 220KW Frequency VFD AC Drive Manufacturer Vector Control

 

 

 

High speed accuracy and wide speed range
 
Steady speed accuracy: ±0.5% (SVC), ±0.02% (VC)
Speed range: 1:200 (SVC), 1:1000 (VC)
Heavy load overload capability:
110% rated current for long-term stable operation
150% rated current for 1 minute
180% rated current 10s
 
 
High torque in low speed, fast response
 
Load capacity in low speed:
VF: 180%@0.50Hz
SVC: 180%@0.25Hz
VC: 200%@0.00Hz
Load 0%->100%@50HZ
Load 100%->0%@50HZ
Rapid response to impact loads
 
 
Powerful internal logic
 
1,Built-in up to 6 sets of delay functions, awide variety of input sources, the output can be used as a variety of other built-in module inputs.
 
2,Built-in up to 4 sets of comparator units, any input, multiple comparison functions, the output can be used as a variety of other built in module inputs.
 
3,Built-in up to 4 sets of logic units, arbitrary inputs, multiple logic operations, and outputs can be used as inputs for various other built in modules.
 
4,The above modules can be used alone or in combination to achieve complex internal logic functions to meet various applications, saving
peripheral equipment and wiring

 

Technical Specifications

 

Item Specification
Input Input Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range -15%~10%
Input frequency 50Hz / 60Hz,fluctuation less than 5%
Output Output Voltage 3phase:0~input voltage
Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

Control Control mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating mode Speed control,Torque control(SVC and VC)
Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

Frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multi point, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Over-voltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Under-voltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

Vdc Min control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump under-voltage fault

Carrier frequency 1kHz~12kHz(Varies depending on the type)
Startup method Direct start (can be superimposed DC brake); speed tracking start
Stop method Deceleration stop (can be superimposed DC braking); free to stop
Main control function Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN
Function Keypad LED Digital keyboard and LCD keypad(option)
Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG card Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

Protection Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
Environment Installation location Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude 0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
Ambient temperature -10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
Humidity Less than 95%RH, without condensing
Vibration Less than 5.9 m/s2 (0.6 g)
Storage temperature -20°C ~ +60°C
Others Installation Wall-mounted, floor-controlled cabinet, transmural
Protection level IP20
cooling method Forced air cooling
EMC CE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment

 

 

Vector Control VFD AC Drive 185KW 200KW 220KW Frequency 440V 0

 

Product Application

 

Vector Control VFD AC Drive 185KW 200KW 220KW Frequency 440V 1

 

Vector Control VFD AC Drive 185KW 200KW 220KW Frequency 440V 2

 

 

FAQ:

 

1. What voltage range can you support?

 

Single-phase 220v input, single-phase 220v output;
Single-phase 220v input, three-phase 220v output;
Three-phase 220v input, three-phase 220v output;
Single-phase 220v input, three-phase 380v output;

 

2. What is the standard of package?

 

Below 37kw, it's carton package; 45kw and above, it's wooden package.

 

3. Do you accept OEM business?

 

We accept OEM and ODM with your autherization.

Leave a Message