Tayfun from TurkeyVeikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
-
Cristian from ChileIt’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
-
Brahim assad from SyriaVEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Place of Origin | China |
---|---|
Brand Name | VEIKONG |
Certification | CE |
Model Number | VFD500M |
Minimum Order Quantity | 1 |
Price | Negotiable |
Packaging Details | Carton and Wooden Box |
Delivery Time | 3 days, depend on the order quantity |
Payment Terms | Western Union, T/T, L/C, D/A, D/P, PayPal |
Supply Ability | 15000pcs per Month |
Product Name | Mini 0.75KW 1.5KW VFD | Power Range | 0.75-4kw |
---|---|---|---|
Voltage | 220V And 380V | Size | 145*75*115mm |
Protection Level | IP20 | Keyboard | LED |
High Light | 1.5KW VFD Variable Frequency Drive,0.75KW VFD Variable Frequency Drive,Vector Control 1.5 kw vfd |
Mini 0.75KW 1.5KW VFD With Vector Control For Water Pump And Fans
Features and Functions
1. V/F and sensorless vector control
2. Starting torque 150% at 0.25Hz in SVC
3. HDI and HDO function
4. Automatic torque boost
5. Easy startup with simplified parameters
6. 2-Independent S-ramps
7. Vector and torque control
8. Variable DC injection braking
9. Energy saving
10. Self-definition parameter
11. In-built dynamic braking unit
Technical Specification
Item |
Specifiation |
|
Input |
Inuput Voltage |
1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
Allowed Voltage fluctuation range |
-15%~10% |
|
Input frequency |
50Hz / 60Hz,fluctuation less than 5% |
|
Output |
Output Voltage |
1/3phase:0~input voltage |
Overload capacity |
General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current |
|
Control |
Control mode |
V/f control Sensorless flux vector control without PG card(SVC) |
Operating mode |
Speed control,Torque control(SVC) |
|
Speed range |
1:100 (V/f) 1:200( SVC) |
|
Speed control accuracy |
±0.5% (V/f) ±0.2% (SVC) |
|
Speed response |
5Hz(V/f) 20Hz(SVC) |
|
frequency range |
0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) |
|
Input frequency resolution |
Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% |
|
Startup torque |
150%/0.5Hz(V/f) 180%/0.25Hz(SVC) |
|
Torque control accuracy |
SVC:within 5Hz10%,above 5Hz5% VC:3.0% |
|
V/f curve |
V / f curve type: straight line, multipoint, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost |
|
Frequency giving ramp |
Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s |
|
DC bus voltage control |
Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;
Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure
VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault |
|
Carrier frequency |
1kHz~16kHz(Varies depending on the type) |
|
Startup method |
Direct start (can be superimposed DC brake); speed tracking start |
|
Stop method |
Deceleration stop (can be superimposed DC braking); free to stop |
|
Maincontrol function |
Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN |
|
Function |
Keypad |
LED Digital keypad and LCD keypad(option)and external LED display |
communication |
Standard: MODBUS communication |
|
Input terminal |
Size A:4 digital input terminals and 1 analog input terminals Size B:5 digital input terminals,one of which supports high-speed pulse input up to 50kHz;2 analog input terminalssupport 0 ~ 10V voltage input or 0 ~ 20mA current input; |
|
Output terminal |
Size A 1 digital output terminal; 1 relay output terminal(Support NO only ) 1 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output; Size B 1 digital output terminal; 1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output; 1 relay output terminal(SUPPORT NO AND NC) 1 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output; |
|
Protection |
Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function |
|
Environment |
Installation location |
Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude |
0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m |
|
Ambient temperature |
-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C |
|
Humidity |
Less than 95%RH, without condensing |
|
Vibration |
Less than 5.9 m/s2 (0.6 g) |
|
Storage temperature |
-20°C ~ +60°C |
|
Others |
Installation |
Wall-mounted, floor-controlled cabinet, transmural |
Protection level |
IP20 |
|
cooling method |
Forced air cooling FOR SIZE B ,SIZE A(NATURAL COOLING) |
Model Range
Model |
Power capacity (KVA) |
Input current (A) |
Output current(A) |
Adaptable Motor (KW) |
SIZE |
Brake Unit |
|
Heavy load |
Light load |
||||||
3 phase: 380V-480V,50/60Hz |
|||||||
VFD500M-R75GT4B |
1.6 |
3.2 |
2.5 |
4.2 |
0.75 |
SIZE B |
Internal |
VFD500M-1R5GT4B |
2.8 |
4.7 |
4.2 |
5.6 |
1.5 |
||
VFD500M-2R2GT4B |
3.7 |
7.8 |
5.6 |
9.4 |
2.2 |
||
VFD500M-4R0GT4B |
6.2 |
11.6 |
9.4 |
10.5 |
3.7 |
||
VFD500M-5R5GT4B |
8.6 |
15.6 |
13.0 |
17.0 |
5.5 |
SIZE C |
Internal |
VFD500M-7R5GT4B |
11.2 |
20.5 |
17.0 |
23.0 |
7.5 |
||
1 phase: 200-240V,50/60Hz |
|||||||
VFD500M-R40GS2B |
1.2 |
6.9 |
2.8 |
3.2 |
0.4 |
SIZEA |
Internal |
VFD500M-R75GS2B |
2.1 |
12.2 |
4.5 |
4.8 |
0.75 |
||
VFD500M-1R5GS2B |
3.1 |
17.0 |
8.0 |
10.6 |
1.5 |
SIZEB |
|
VFD500M-2R2GS2B |
4.1 |
21.0 |
10.6 |
12.5 |
2.2 |
||
3 phase: 200V-240V,50/60Hz |
|||||||
VFD500M-R40GT2B |
1.2 |
4 |
2.8 |
3.2 |
0.4 |
Size B
|
Internal |
VFD500M-R75GT2B |
2.1 |
7.1 |
4.5 |
4.8 |
0.75 |
||
VFD500M-1R5GT2B |
3.1 |
11.3 |
8.0 |
10.6 |
1.5 |
||
VFD500M-2R2GT2B |
4.1 |
14.5 |
10.6 |
12.5 |
2.2 |
Product Application
FAQ:
1. How to choose suitable VFD for my machine?
Please send us your machine details, we will provide you most suitable model type.
2. Do you support OEM service?
Yes, we support OEM and ODM.
We export to the South America, Europe, India, the Middle East, Asia, Africa, etcs.