Place of Origin | China |
---|---|
Brand Name | VEIKONG |
Certification | CE |
Model Number | VFD500-PV |
Minimum Order Quantity | 1 |
Price | Negotiable |
Packaging Details | the power less than 45kw use Carton, starting from 45kw use Wooden case |
Delivery Time | 3 days, depend on the order quantity |
Payment Terms | L/C, T/T, Western Union |
Supply Ability | 15000pcs per Month |
Product Name | 18.5kw 22kw Inverter | Max InputDC Voltage | 450vdc Or 800v Dc |
---|---|---|---|
Oem | Available | Type | AC Inverter/Converter |
Output Frequency | 50Hz/60Hz | Display | LCD,LED |
High Light | 18.5kw Single Phase Solar Pump Inverter,22kw Single Phase Solar Pump Inverter,18.5kw single phase solar pump controller |
Solar pump inverter 18.5kw 22kw 220V single phase for agricultural irrigation
Key Advantages:
1. MPPT efficiency more than 99%.
Techincal Parameters:
1. Wake up and sleep function parameters:
P47.05 | Light detection threshold | If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop | 0Hz |
P47.06 | Light detection time | See P47.05 for explanation. | 60s |
P47.07 | Light weak wake up time | After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. | 600s |
2. Dry runing protection function parameters:
P24.12 | Dry run/Unload protection option |
0: No offload detection is performed; 1: Enable dry run detection |
1 |
P24.13 | Dry run/Unload detection level |
0.0 to 200.0% The percentage of motor rated current. |
0.0% |
P24.14 | Dry run Unload detection time | 0.000s~60.000s | 30.000s |
P24.15 | Unload detection offset frequency |
0.00Hz~Fmax Detection frequency=Fmax-P24.15
|
5.00Hz |
P24.16 | Reset time of dry run protection | 0.0~6000.0 | 240.0s |
P23.21 | Dry run detection mode |
0000:Coast stop 1000:Fast stop 3000:Continue to run |
0000 |
3. Water full protection function parameters:
P47.18 | Full water level detection channel |
0:ineffective 1:AI1 2:AI2 3:AI3 4:AI4 Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same. |
0 |
P47.19 | Full water level detection value |
0.0~100.0%
|
0.0% |
P47.20 | Full water level detection time |
0.0~3000.0s When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.
|
10.0s |
P47.21 | Full water recovery time |
0.0~3000.0s When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay |
10.0s |
Support optional LCD keypad
Support optional GPRS Module
VEIKONG Solar pump special parameter User mode fast quick start
VEIKONG Solar pump special parameter User mode fast quick start
Function code | Name | Description | Default | Property |
47 Group solar pumping special group | ||||
P00.03 | RESET |
0:NO ACTION 11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter 12:Restore default to factory parameter 13:Clear tripping record |
0 | ★ |
P00.06 | Source of the Operation Command |
0:keypad 1:terminal 2:communication Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc |
0 | ★ |
P00.07 | Numeric frequency setting | 00.00Hz~maximum frequency | 50.00Hz | ☆ |
P00.11 | Application Macro |
01:Output three phase 50HZ 02:Output three phase 60hz 21:Output single phase with capacitor 50hz 22:Output single phase with capacitor 60hz 31:Output single phase without capacitor 50hz 32:Output single phase without capacitor 60hz |
00 | ★ |
P01.06 | Maximum frequency | 10.00~600.00Hz | 50.00Hz | ★ |
P01.08 | Upper limit frequency | Lower limit frequency-maximum frequency | 50.00Hz | ☆ |
P07.03 | Relay 1 Output terminal function group(T1A T1B T1C) |
0:No function 1:READY 2:RUN 3:Error1(stop fault) 4:Error2(same as Error1 except undervoltage) 5:Warning output(fault but in running) |
3 | ☆ |
P11.01 | AC asynchronous motor TYPE |
0:Three phase AC asynchronous motor 1:Single phase AC asynchronous motor without starting capacitor |
0 | ★ |
P11.02 | Motor rated power |
0.1kW~710.0kW Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6 Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use |
Depend | ★ |
P11.03 | Motor rated voltage | 10V~2000V | Depend | ★ |
P11.04 | Motor rated current |
P11.02<30kW:0.01A P11.02>=30kW:0.1A |
Depend | ★ |
P11.05 | Motor rated frequency | 1.00Hz~600.00Hz | 50.00Hz | ★ |
P11.06 | Motor rated RPM | 1~60000rpm | Depend | ★ |
P21.00 | Monitoring display |
0:Standard mode (display frequency only) 1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage |
0 | ★ |