• Shenzhen Veikong Electric Co., Ltd.
    Tayfun from Turkey
    Veikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
  • Shenzhen Veikong Electric Co., Ltd.
    Cristian from Chile
    It’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
  • Shenzhen Veikong Electric Co., Ltd.
    Brahim assad from Syria
    VEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Contact Person : Terry
Phone Number : 008613923736332
WhatsApp : +8613923736332
VEIKONG General Purpose 1 Hp Vfd Single Phase Ac Drive Inverters
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VFD500
Minimum Order Quantity 1
Price Negotiable
Packaging Details the power less than 45kw use Carton, starting from 45kw use Wooden case
Delivery Time 3 days, depend on the order quantity
Payment Terms L/C, T/T, Western Union
Supply Ability 15000pcs per Month
Product Details
Product Name 1hp VFD Power 1hp/3hp/10hp
Warranty 18 Monthes Load Light Load/heavy Load
Output Voltage 0-380v Keypad LED LCD
High Light

VEIKONG 1 Hp Vfd Single Phase

,

1 Hp Single Phase Ac Drive

,

VEIKONG Single Phase Ac Drive

Product Description
VEIKONG  hot selling VFD
 
VFD500M is high performance vector control mini vfd
 
VFD500 is high performacne general vfd
 
VFD550 is high perfromance special vfd with positional control.
 
VFD530 is high performance special vfd with lifting function, support 2 PID, support Synchronous and asynchronous motors
 
VFD500-PV is solar pump inverter.
 
VFD510 is IP65 inverter

 

Drive design & features
VEIKONG continues to make applications even smaller by combining the compact designed drive with
the light, efficient design of a synchronous motor. Use Side-by-Side installation for an even more compact setup.
Finless models available.
 
Independent duct design
Independent air duct design, effectively preventing dust entering inverter, causing short-circuit and other faults and
improving reliability. Use bigger air volume and long life cooling fan effectively reduces the internal temperature rise of the inverter
and ensures reliable and stable operation of inverter
 
Perfect protection system
Designed for 10 years of maintenance-free operation.
Cooling fan, capacitors, relays, and IGBTs have been carefully selected and designed for a life expectancy up to ten years.
 
Rapid response to impact loads
When it meets with sudden load change, inverter can quickly restore the speed, reduce the speed fluctuation, and ensure the
production stability and high quality finished products.

 

Techincal Parameters:

 

Item Specifiation
Input Inuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

  Allowed Voltage fluctuation range -15%~10%
  Input frequency 50Hz / 60Hz,fluctuation less than 5%
Output Output Voltage 3phase:0~input voltage
  Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

Control Control mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

  Operating mode Speed control,Torque control(SVC and VC)
  Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

  Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

  Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

  frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

 

 

VEIKONG General Purpose 1 Hp Vfd Single Phase Ac Drive Inverters 0

 

VEIKONG VFD APPLICATION:

VEIKONG General Purpose 1 Hp Vfd Single Phase Ac Drive Inverters 1

 

 

Mode Range

Model

Power capacity

(KVA)

Input current

(A)

Output current(A)

Adaptable Motor

(KW)

SIZE Brake Unit
Heavy load Light load
Three phase: 380-480V,50/60Hz
VFD500-R75GT4B 1.5 3.4 2.5 4.2 0.75 SIZE A Internal
VFD500-1R5GT4B 3 5 4.2 5.6 1.5
VFD500-2R2GT4B 4 5.8 5.6 9.4 2.2
VFD500-4R0G/5R5PT4B 5.9 10.5 9.4 13.0 3.7
VFD500-5R5G/7R5PT4B 8.9 14.6 13.0 17.0 5.5 SIZE B
VFD500-7R5G/011PT4B 11 20.5 17.0 23.0 7.5
VFD500-011G/015PT4B 17 26.0 25.0 31.0 11 SIZE C Internal
VFD500-015G/018PT4B 21 35.0 32.0 37.0 15
VFD500-018G/022PT4B 24 38.5 37.0 45.0 18.5 SIZE D
VFD500-022G/030PT4B 30 46.5 45.0 57.0 22
VFD500-030G/037PT4 40 62.0 60.0 75.0 30 SIZE E option
VFD500-037G/045PT4 50 76.0 75.0 87.0 37
VFD500-045G/055PT4 60 92.0 90.0 110.0 45 SIZE F
VFD500-055G/075PT4 75 113.0 110.0 135.0 55
VFD500-075G/090PT4 104 157.0 152.0 165.0 75 SIZE G
VFD500-090G/110PT4 112 170.0 176.0 210.0 90 External
VFD500-110G/132PT4 145 220.0 210.0 253.0 110 SIZE H
VFD500-132G/160PT4 170 258.0 253.0 304.0 132 SIZE I
VFD500-160G/185PT4 210 320.0 304.0 360.0 160
VFD500-185G/200PT4 245 372.0 360.0 380.0 185 SIZE J
VFD500-200G/220PT4 250 380.0 380.0 426.0 200
VFD500-220G/250PT4 280 425.0 426.0 465.0 220 SIZE K
VFD500-250G/280PT4 315 479.0 465.0 520.0 250
VFD500-280G/315PT4 350 532.0 520.0 585.0 280 SIZE L
VFD500-315G/355PT4 385 585.0 585.0 650.0 315
VFD500-355G/400PT4 420 638.0 650.0 725.0 355 SIZE M
VFD500-400G/450PT4 470 714.0 725.0 820.0 400
VFD500-450G/500PT4 530 800.0 820.0 / 450 SIZE N
VFD500-500G/560PT4 580 880.0 900.0 / 500
VFD500-560G/630PT4 630 950.0 980.0 / 560 SIZE O
VFD500-630GT4 710 1080 1120. / 630 SIZE O
VFD500-710GT4 790 1200 1260 / 710 SIZE O
Single phase :220V ,50/60HZ
VFD500-R40GS2 1.3 6.0 3.2 5.6 0.4 SIZE A Inbuilt
VFD500-R75GS2 2.4 11.0 5.6 8.0 0.75 SIZE A
VFD500-1R5GS2 3.5 15.0 8.0 10.6 1.5 SIZE A
VFD500-2R2GS2 5.5 25.0 10.6 14.0 2.2 SIZE A
VFD500-4R0GS2 7.7 35.0 17.0 23.0 4.0 SIZE B
VFD500-5R5GS2 8.9 53.0 25.0 31.0 5.5 SIZE C
VFD500-7R5GS2 11 67.0 32.0 37.0 7.5 SIZE C
 

VFD500 parameter distribution list

 

Classification Parameter group Page
Common parameters 00:Basic function Page 30
01:Frequency source selection Page 32
02:Start and stop Page 37
03:Ramp and S curve Page 39
04: Analog and pulse input Page 41
05:Analog and pulse output Page 45
06: Multi-function Digital input (DI) Page 46
07: Multi-function Digital output(DO) Page 49
08:Digital Output setting Page 51
Motor control 10:Encoder type Page 53
11:Motor1 parmeter Page 54
12:Motor1 VFcontrol parameter Page 56
13:Motor1 Vector controlparameter Page 58
14:Torque control Page 59
16:Energy saving control Page 61
Display and protection 20:User-defined parameters Page 62
21:Keypad and display Page 63
22:AC Drive configuration Page 65
23:Drive protection function setting Page 67
24:Motor protection parameter Page 70
25:Fault tracking parameter Page 72
26:Fault recording parameter Page 72
27:Monitoring parameter Page 74
Communication 30:Modbus communication Page 75
Application 40:Process PID Function Page 77
41:Sleep function Page 81
42:Simple PLC Page 82
43:Programmable delay unit Page 84
44:Comparator and logic unit/controller Page 86
45:Multifunction counter Page 90
Motor 2 60:Motor2 basic parameter Page 91
61:Motor2 parameter Page 91
62:Motor2 VF control parameter Page 92
63:Motor2 vector control parameter Page 92
 

 

 


 
 
 
 