• Shenzhen Veikong Electric Co., Ltd.
    Tayfun from Turkey
    Veikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
  • Shenzhen Veikong Electric Co., Ltd.
    Cristian from Chile
    It’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
  • Shenzhen Veikong Electric Co., Ltd.
    Brahim assad from Syria
    VEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Contact Person : Terry
Phone Number : 008613923736332
WhatsApp : +8613923736332
ROHS standard 220v Single Phase Output Vfd Device / Dc To Ac Vfd Drives
Place of Origin CHINA
Brand Name VEIKONG
Certification CE, ROHS
Model Number VFD500
Minimum Order Quantity 1
Price negotiable
Packaging Details <45kw inverter be used carton package, ≥45kw be used wood case package
Delivery Time depends on quantities
Payment Terms T/T, Western Union, L/C
Supply Ability 1000 units per week
Product Details
Product Name Variable Frequency Drive Voltage 220v/380v
Keypad LED And LCD Type AC Frequency Inverter
Warranty 18 Months Protection Overload,Overvoltage,IP20,Short Circuit,over Heat
High Light

220v Single Phase Output Vfd

,

ROHS 220v Single Phase Output Vfd

,

ROHS Dc To Ac Vfd Drives

Product Description

Single Phase Three Phase Vfd, 220v 380v With Vector Control Inverter

 

VFD500 features and technical data sheet:

 

1, Use newest software and unique design, the performance can replace famous brands.

 

2, Standard built in EMC C3 filter.
 
3, Support modbus485, canopen, profinet communciation.
 
4,Support optional LCD keypad and dual display keypad. support PC tools.
 
5, Sleeping function and energy saving function as well as in built PLC programming
 
6, Support vf control, senserless vector control without PG card and sensor vector control with different kind of PG card.
 
 
Item Specifiation
Input Inuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

  Allowed Voltage fluctuation range -15%~10%
  Input frequency 50Hz / 60Hz,fluctuation less than 5%
Output Output Voltage 3phase:0~input voltage
  Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

Control Control mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

  Operating mode Speed control,Torque control(SVC and VC)
  Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

  Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

  Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

  frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

  Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

  Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

  Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

  V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

  Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

  DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

  Carrier frequency 1kHz~12kHz(Varies depending on the type)
  Startup method

Direct start (can be superimposed DC brake); speed tracking start


VFD500 11kw and 15kw appearance and size

 

ROHS standard 220v Single Phase Output Vfd Device / Dc To Ac Vfd Drives 0

 

VFD500 18kw and 22kw appearance and size

ROHS standard 220v Single Phase Output Vfd Device / Dc To Ac Vfd Drives 1

 

ROHS standard 220v Single Phase Output Vfd Device / Dc To Ac Vfd Drives 2

 

VFD500 inverter models and technical data

Model

Power capacity

(KVA)

Input current

(A)

Output current(A)

Adaptable Motor

(KW)

SIZE Brake Unit
Heavy load Light load
Three phase: 380-480V,50/60Hz
VFD500-R75GT4B 1.5 3.4 2.5 4.2 0.75 SIZE A Internal
VFD500-1R5GT4B 3 5 4.2 5.6 1.5
VFD500-2R2GT4B 4 5.8 5.6 9.4 2.2
VFD500-4R0G/5R5PT4B 5.9 10.5 9.4 13.0 3.7
VFD500-5R5G/7R5PT4B 8.9 14.6 13.0 17.0 5.5 SIZE B
VFD500-7R5G/011PT4B 11 20.5 17.0 23.0 7.5
VFD500-011G/015PT4B 17 26.0 25.0 31.0 11 SIZE C Internal
VFD500-015G/018PT4B 21 35.0 32.0 37.0 15
VFD500-018G/022PT4B 24 38.5 37.0 45.0 18.5 SIZE D
VFD500-022G/030PT4B 30 46.5 45.0 57.0 22
VFD500-030G/037PT4 40 62.0 60.0 75.0 30 SIZE E option
VFD500-037G/045PT4 50 76.0 75.0 87.0 37
VFD500-045G/055PT4 60 92.0 90.0 110.0 45 SIZE F
VFD500-055G/075PT4 75 113.0 110.0 135.0 55
VFD500-075G/090PT4 104 157.0 152.0 165.0 75 SIZE G
VFD500-090G/110PT4 112 170.0 176.0 210.0 90 External
VFD500-110G/132PT4 145 220.0 210.0 253.0 110 SIZE H
VFD500-132G/160PT4 170 258.0 253.0 304.0 132 SIZE I
VFD500-160G/185PT4 210 320.0 304.0 360.0 160
VFD500-185G/200PT4 245 372.0 360.0 380.0 185 SIZE J
VFD500-200G/220PT4 250 380.0 380.0 426.0 200
VFD500-220G/250PT4 280 425.0 426.0 465.0 220 SIZE K
VFD500-250G/280PT4 315 479.0 465.0 520.0 250
VFD500-280G/315PT4 350 532.0 520.0 585.0 280 SIZE L
VFD500-315G/355PT4 385 585.0 585.0 650.0 315
VFD500-355G/400PT4 420 638.0 650.0 725.0 355 SIZE M
VFD500-400G/450PT4 470 714.0 725.0 820.0 400
VFD500-450G/500PT4 530 800.0 820.0 / 450
VFD500-500G/560PT4 580 880.0 900.0 / 500
VFD500-560G/630PT4 630 950.0 980.0 / 560 SIZE N
VFD500-630GT4 710 1080 1120. / 630 SIZE N
VFD500-710GT4 790 1200 1260 / 710 SIZE N
Single phase :220V ,50/60HZ
VFD500-R40GS2 1.3 6.0 3.2 5.6 0.4 SIZE A Inbuilt
VFD500-R75GS2 2.4 11.0 5.6 8.0 0.75 SIZE A
VFD500-1R5GS2 3.5 15.0 8.0 10.6 1.5 SIZE A
VFD500-2R2GS2 5.5 25.0 10.6 14.0 2.2 SIZE A
VFD500-4R0GS2 7.7 35.0 17.0 23.0 4.0 SIZE B
VFD500-5R5GS2 8.9 53.0 25.0 31.0 5.5 SIZE C
VFD500-7R5GS2 11 67.0 32.0 37.0 7.5 SIZE C
 

 

 


 


 
Leave a Message