• Shenzhen Veikong Electric Co., Ltd.
    Tayfun from Turkey
    Veikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
  • Shenzhen Veikong Electric Co., Ltd.
    Cristian from Chile
    It’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
  • Shenzhen Veikong Electric Co., Ltd.
    Brahim assad from Syria
    VEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Contact Person : Terry
Phone Number : 008613923736332
WhatsApp : +8613923736332
AC380V DC900V 3 Phase Solar Pump Inverter 132kw 160kw 185kw With MPPT
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VFD500-PV
Minimum Order Quantity 1
Price Negotiable
Packaging Details the power less than 45kw use Carton, starting from 45kw use Wooden case
Delivery Time 3 days, depend on the order quantity
Payment Terms L/C, T/T, Western Union
Supply Ability 15000pcs per Month
Product Details
Product Name 3 Phase INVERTER Voltage 380v AC 900V DC
Output Power 132KW 160KW 185KW Protection Level IP20/IP65
Type Three Phase OEM YES
High Light

AC380V 3 Phase Solar Pump Inverter

,

185kw 3 Phase Solar Pump Inverter

,

DC900V 3 Phase Solar Pump Controller

Product Description

AC380V DC900V 3 Phase Solar Pump Inverter 132kw 160kw 185kw With MPPT

 

3 Phase 380V AC 900V DC Solar Pump Inverter 132kw 160kw 185kw With MPPT

 

Product Details and Features:

 

1. Operates without grid directly from photovoltaic (PV) cells

 

2. Automatic start and stop with solar radiation

 

3. Built-in maximum power point tracking (MPPT)

 

4. Easy installation and set-up for serial production

 

5. Compatible with all pump types

 

6. Good ROI (Return on Investment) against diesel powered pumping

 

7. Compact and uniform drive module design (IP20)

 

8. Dual supply capability with change over switch - solar and grid compatible

 

9. Sensorless vector control of induction motors and permanent magnet motors

 

10. Energy saving function and dry run self learning function 11 GPRS monitoring control via PC and Mobile

 

 

Electrical Specifications and Power degree
 
PV input
Maxiumum input DC voltage 400V DC
Recommended MPPT voltage range 250~350V DC
Recommended input Operation Voltage 310V DC
Grid or backup generator input
Input voltage Single phase 220V(-15%~30%)
Output Specification
Rated output voltage 3PH 220V
Output frequency 0~500.00Hz (default: 0~50.00Hz)
380V Solar Pumping Inverter
Input Specification
PV input
Maxiumum input DC voltage 800V DC
Recommended MPPT voltage range 450~650V DC
Recommended input Operation voltage 540V DC
Grid or backup generator input
Input voltage Three phase 380V(-15%~30%)
Output specification
Rated ouput voltage 3PH 380V
Output frequency 0~500.00Hz (default: 0~50.00Hz)
Protection
Built-in Protection Lighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.

 

 

 
Product Application
 
AC380V DC900V 3 Phase Solar Pump Inverter 132kw 160kw 185kw With MPPT 0
AC380V DC900V 3 Phase Solar Pump Inverter 132kw 160kw 185kw With MPPT 1

 

 
1. How to design solar PV water pump system?
Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
the inverter. If needed, we will provide technical support online.
 
2. How to make the water pump system work without sunshine?
Usually, solar PV water pump system can meet the needs of pumping water.
If there is no sunshine, the system will not work. But out inverter could also support AC input. So,
connect the power grid or diesel power generation to the inverter, the pumping system will work. If
necessary, keep switch and interface locations during the system design
 
3. How to check and solve basic problem of inverter trips and error
a:Check the total vmp and voc of solar panels ,solar panel technical data
b:Check motor pump power and rated current
c: Check the distance between motor and inverter
d: Check trip record r25.00 r25.01 25.02 25.03 r26.00 r26.01 r26.02 r26.03 r26.08 r26.09 r26.10 r26.11
e: Check troubleshooting fault and find relevant solutions
f : Check if motor insulation has been damaged or motor is blocked

 

 