2.2KW 4KW GPRS Pump Inverter Solar VFD For Solar Irrigation System
Place of Origin | China |
---|---|
Brand Name | VEIKONG |
Certification | CE |
Model Number | VFD500-PV |
Minimum Order Quantity | 5 |
Price | Negotiable |
Packaging Details | the power less than 45kw use Carton, starting from 45kw use Wooden case |
Delivery Time | depend on the order quantity |
Payment Terms | L/C, T/T, Western Union |
Supply Ability | 15000pcs per Month |
Product Details
Product Name | Solar Pump Inverter | Voltage | 220v/380v |
---|---|---|---|
Frequency | 50hz/60hz | Display | LED+LCD |
Protection | Ip20 And Ip65 | Color | White And Blue |
High Light | 2.2KW Pump Inverter Solar,2.2KW Solar VFD,4KW Pump Inverter Solar |
Product Description
2.2KW 4KW GPRS Pump Inverter Solar VFD For Solar Irrigation System
2.2KW 4KW Solar Pump Inverter GPRS Solar VFD For Pump Solar Irrigation System
VEIKONG IS Solar Ac Pump Controller chinese manufacturer
Performance features:(220v 0.75kw-75kw, 380v 0.75kw-250kw)
Features:
- Support Hybrid solar power and ac power at same time
- Support optional LCD keypad, you will know all parameters meaning , no need user manual
- Support optional GPRS module to remote control and monitor solar pumping situation
- Support optional output reactor to protect the motor
- Support water full, dry running, wake and sleep protection functions.
Electrical Specifications
PV input | |
Maxiumum input DC voltage | 400V DC |
Recommended MPPT voltage range | 250~350V DC |
Recommended input Operation Voltage | 310V DC |
Grid or backup generator input | |
Input voltage | Single phase 220V(-15%~30%) |
Output Specification | |
Rated output voltage | 3PH 220V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
380V Solar Pumping Inverter | |
Input Specification | |
PV input | |
Maxiumum input DC voltage | 800V DC |
Recommended MPPT voltage range | 450~650V DC |
Recommended input Operation voltage | 540V DC |
Grid or backup generator input | |
Input voltage | Three phase 380V(-15%~30%) |
Output specification | |
Rated ouput voltage | 3PH 380V |
Output frequency | 0~500.00Hz (default: 0~50.00Hz) |
Protection | |
Built-in Protection | Lighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc. |
1. GPRS (support 2g/3g/4g internet)
2. Output reactor
3. LCD keypad
Model Range
Drive Model | Related Voltage | Max DC input voltage (V) | Rated output current (A) | Applicable water pump (KW) | SIZE |
VFD500M-20T00150-PV | 220V | 800 | 7 | 1.5 | SIZE A |
VFD500M-20T00220-PV | 220V | 800 | 10.6 | 2.2 | SIZE A |
VFD500M-40T00150-PV | 380V | 800 | 4.2 | 1.5 | SIZE A |
VFD500M-40T00220-PV | 380V | 800 | 6 | 2.2 | SIZE A |
VFD500-20T00150-PV | 220V | 800 | 7 | 1.5 | SIZE A |
VFD500-20T00220-PV | 220V | 800 | 10.6 | 2.2 | SIZE A |
VFD500-20T00400-PV | 220V | 800 | 17 | 4 | SIZE A |
VFD500-40T00150-PV | 380V | 800 | 4.2 | 1.5 | SIZE A |
VFD500-40T00220-PV | 380V | 800 | 6 | 2.2 | SIZE A |
VFD500-40T00400-PV | 380V | 800 | 9.4 | 4 | SIZE A |
VFD500-40T00550-PV | 380V | 800 | 13 | 5.5 | SIZE B |
VFD500-40T00750-PV | 380V | 800 | 17 | 7.5 | SIZE B |
VFD500-40T01100-PV | 380V | 800 | 25 | 11 | SIZE C |
VFD500-40T01500-PV | 380V | 800 | 32 | 15 | SIZE C |
VFD500-40T01850-PV | 380V | 800 | 38 | 18.5 | SIZE D |
VFD500-40T02200-PV | 380V | 800 | 46 | 22 | SIZE D |
VFD500-40T03000-PV | 380V | 800 | 60 | 30 | SIZE E |
VFD500-40T03700-PV | 380V | 800 | 75 | 37 | SIZE E |
VFD500-40T04500-PV | 380V | 800 | 96 | 45 | SIZE F |
VFD500-40T05500-PV | 380V | 800 | 112 | 55 | SIZE F |
VFD500-40T07500-PV | 380V | 800 | 150 | 75 | SIZE G |
VFD500-40T09000-PV | 380V | 800 | 176 | 90 | SIZE G |
VFD500-40T11000-PV | 380V | 800 | 210 | 110 | SIZE H |
VFD500-40T13200-PV | 380V | 800 | 253 | 132 | SIZE I |
VFD500-40T16000-PV | 380V | 800 | 304 | 160 | SIZE I |
VFD500-40T18500-PV | 380V | 800 | 340 | 185 | SIZE J |
VFD500-40T20000-PV | 380V | 800 | 377 | 200 | SIZE J |
Trial run(How to start solar pump inverter)
Make sure all cables connections of solar panel and pump motor correct and no
need to set any parameter, if you want to set parameter, you can do as follows.
Step 1: (Keypad control):Set motor parameter P11.02- P11.06 as per motor pump name
plate If dry run protection is required, measure the unload protection current(see details in
user manual chapter for dry run function) If dry run protection not required then miss this step
and go to step 2.
Step 2: Set other related special solar pump parameters for optimization if needed.
Step 3: After trial run finishing, if motor pump still not output water when inverter is running
more than 40 Hz. Please disconnect the power supply and replace any two-phase wiring of
the motor
Technical Questions and solutions
1. How to achieve Automatic start after stop?
If it is controlled by keyboard, so there is no need to set any parameter(P47.03 waiting time)If you want to
control by external switch. First set P00.06=1 and use a wire or switch to connect com and DI1,When the
switch is closed, the drive run, when the switch is open, the drive stop
2. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
143.Use level probe in the well for protection against dry running
1 st solution: See self learning of dry run(For LED display)
2 nd solution: do it manually Set P24.13=30%-60%(as per real empty load current percentage based on
rated current) and P24.14 P24.16 and P23.21
3 rd solution: If your sensor is digital switch, just short D4 and com
4 th solution: If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and
P41.03-P41.06