• Shenzhen Veikong Electric Co., Ltd.
    Tayfun from Turkey
    Veikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
  • Shenzhen Veikong Electric Co., Ltd.
    Cristian from Chile
    It’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
  • Shenzhen Veikong Electric Co., Ltd.
    Brahim assad from Syria
    VEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Contact Person : Terry
Phone Number : 008613923736332
WhatsApp : +8613923736332
380v 2200w Three Phase Solar Inverter Solar Vfd Drive With LCD Keypad
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VFD500-PV
Minimum Order Quantity 1
Price Negotiable
Packaging Details the power less than 45kw use Carton, starting from 45kw use Wooden case
Delivery Time 3 days, depend on the order quantity
Payment Terms L/C, T/T, Western Union
Supply Ability 15000pcs per Month
Product Details
Product Name Three Phase Solar Pump Inverter Current 5.6A/9.4A
Output Type 3 Phase Type DC-AC
Application Water Pump System Frequency 50hz/60hz
High Light

2200w Three Phase Solar Inverter

,

2200w Solar Vfd Drive

,

380v Three Phase Solar Inverter

Product Description

Solar pump inverter 380v 2.2kw 4kw with LCD keypad for irrigation system

 

Features:
 
1, Comprehensive voltage level and power range
Support single phase/three phase 220V, and three phase 380V solar water pump inverter, power from 0.75kW to 160KW
 
2, Easy to use
Simply connect the photovoltaic panel to the inverter, no need to set any parameters,
and the PV pump can be automatically started after power-on
 
3, Multiple protection measures
It has protection functions such as PV over-voltage protection, PV polarity reverse connection alarm, over-temperature automatic derating, etc., which can effectively extend the life of the product
 
4, Advanced MPPT algorithm
Ensure solar power tracking efficiency can reach 99.99%
 
5, GPRS remote monitoring
Supports optional GPRS module, which can realize remote monitoring function of computer webpage and mobile APP
 
6, AC/DC switching scheme
All series of products can realize automatic switching of PV DC input and grid AC input, which can meet 24 hours of no care work
 
7, IP65 solution
Supports IP65 grade cabinet solutions

 
Electrical Specifications and Power degree
 

 

220V

380V

Max input DC voltage

450V

810V

DC voltage range

150~450VDC

300~810VDC

Normal working DC voltage

260V-400V

400V-650V

Recommended input mppt voltage

330V

550V

MPPT efficiency

>99%

Rated output voltage

1/3-phase 220VAC

3-phase 380-480VAC

Output frequency range

50/60Hz

Max efficiency of the machine

99%

Ambient temperature range

-10 °C~50 °C, derating if the temperature is above 40 °C

Cooling method

Air cooling

Protection degree

IP20/IP21

Altitude

Below 1000m; above 1% for every additional 100m.

Standard

CE/ROHS

 
Product Application
 
380v 2200w Three Phase Solar Inverter Solar Vfd Drive With LCD Keypad 0380v 2200w Three Phase Solar Inverter Solar Vfd Drive With LCD Keypad 1
380v 2200w Three Phase Solar Inverter Solar Vfd Drive With LCD Keypad 2380v 2200w Three Phase Solar Inverter Solar Vfd Drive With LCD Keypad 3
 
 
FAQ
 

1. How to achieve Automatic start after stop?
If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
 
2. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
 
3.Use level probe in the well for protection against dry running
First solution: See self learning of dry run
Second solution: do it manually Set P24.13=30%-60%(as per real empty load current percentage based on
rated current) and P24.14 P24.16 and P23.21
Third solution: If your sensor is digital switch ,just short D4 and com
Fourth solution: If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and
P41.03-P41.06
 
4.How to set minimum frequency ( for example) 30hz and maximum 50HZ
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07
 
5.If pump is 60HZ frequency, how to set max frequency?
Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32

 
 