• Shenzhen Veikong Electric Co., Ltd.
    Tayfun from Turkey
    Veikong solar pump inverter is really in very good quality and we also prepared some promotional products for exhibition. We are going to make new orders soon. Last year there was only one local agent and this year, there are more than 8. Some of them only sell Veikong!
  • Shenzhen Veikong Electric Co., Ltd.
    Cristian from Chile
    It’s very good! LCD options make it much easier to use. That’s the strong point, easy of use. And robust. Great PC software.
  • Shenzhen Veikong Electric Co., Ltd.
    Brahim assad from Syria
    VEIKONG VFD500 output frequency is stable when the others are fluctuating. Also output current is less than others, that’s why output frequency is higher too which can save more energy.
Contact Person : Terry
Phone Number : 008613923736332
WhatsApp : +8613923736332
160kw Solar Water Pump Inverter Controller With MPPT 99% PID Controller Solar Vfd
Place of Origin China
Brand Name VEIKONG
Certification CE
Model Number VFD500-PV
Minimum Order Quantity 1
Price Negotiable
Packaging Details the power less than 45kw use Carton, starting from 45kw use Wooden case
Delivery Time depend on the order quantity
Payment Terms L/C, T/T, Western Union
Supply Ability 15000pcs per Month
Product Details
Product Name 160kw Solar Pump Inverter Voltage 380v
Power 160kw /200hp Theory Solar Pump
Warranty 18 Months OEM Available
High Light

160kw Solar Water Pump Inverter

,

160kw Water Pump Inverter Controller

,

99% MPPT Solar Water Pump Inverter

Product Description

160kw solar pump inverter with MPPT 99% PID controller solar vfd

 

 

Advantage

Half of the energy produced around the world is used to operate pumps. Compared to diesel generator pumps, our solar pump inverter are environmentally friendly, with a long lifetime and low maintenance costs. It is independent from the grid and produces no pollution or noise. Typical applications are irrigation, community water supply, fish farming and agriculture.

 

All of our drives have many solar-specific and pump control functions, such as built-in maximum power point tracking and dry run detection, as well as sensorless flow calculation.

 

The maximum power point tracking (MPPT) ensures you to get the best output power possible from your solar panel and it maximizes the performance of your pump along the day while the automatic start and stop with solar radiation can save money and fuel during daylight hours

 

VEIKONG VFD500-PV solar pumping inverter is specially designed for watering system. A high converting efficiency of 99% and advanced MPPT technology make the solar energy fully used. It converts DC power into AC to drive all kinds of motors. The intelligent design protects the pumps from many abnormal cases, such as over-loading, over-voltage, dry-running, over-heating,low frequency and etc.

 

 

Key Features:

1, Support single phase/three phase 220V, and three phase 380V solar water pump inverter, power from 0.75kW to 160KW

2, Simply connect the photovoltaic panel to the inverter, no need to set any parameters.

3, It has protection functions such as overvoltage protection, overcurrent protection, dry runing protection, full water protection.


4, Advanced MPPT algorithm. Ensure solar power tracking efficiency can reach 99.99%

5, Supports optional GPRS module, which can realize remote monitoring function of computer webpage and mobile APP

6, Support PV DC input and grid AC input at same time, which can meet 24 hours of no care work

7, Support LCD keypad, it is easier to monitor system situation.

 

 


Electrical Specifications and Power degree
 
 

 

220V

380V

Max input DC voltage

450V

810V

DC voltage range

150~450VDC

300~810VDC

Normal working DC voltage

260V-400V

400V-650V

Recommended input mppt voltage

330V

550V

MPPT efficiency

>99%

Rated output voltage

1/3-phase 220VAC

3-phase 380-480VAC

Output frequency range

50/60Hz

Max efficiency of the machine

99%

Ambient temperature range

-10 °C~50 °C, derating if the temperature is above 40 °C

Cooling method

Air cooling

Protection degree

IP20/IP21

Altitude

Below 1000m; above 1% for every additional 100m.

Standard

CE/ROHS

 
 
Accessories:
 
1. GPRS (support 2g/3g/4g internet)
 
160kw Solar Water Pump Inverter Controller With MPPT 99% PID Controller Solar Vfd 0
 
2. LCD keypad
 
 
160kw Solar Water Pump Inverter Controller With MPPT 99% PID Controller Solar Vfd 1
 
 
3. Output Reactor

160kw Solar Water Pump Inverter Controller With MPPT 99% PID Controller Solar Vfd 2
 
 
VFD500-PV solar pump inverter picture:
160kw Solar Water Pump Inverter Controller With MPPT 99% PID Controller Solar Vfd 3

 

 

Connect wire diagram

 

160kw Solar Water Pump Inverter Controller With MPPT 99% PID Controller Solar Vfd 4

 

 

 

Techincal Parameters:

 

1. Wake up and sleep function parameters:

 

P47.05 Light detection threshold If the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop 0Hz
P47.06 Light detection time See P47.05 for explanation. 60s
P47.07 Light weak wake up time After the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues. 600s

 

2. Dry runing protection function parameters:

 

P24.12 Dry run/Unload protection option

0: No offload detection is performed;

1: Enable dry run detection

1
P24.13 Dry run/Unload detection level

0.0 to 200.0%

The percentage of motor rated current.

0.0%
P24.14 Dry run Unload detection time 0.000s~60.000s 30.000s
P24.15 Unload detection offset frequency

0.00Hz~Fmax

Detection frequency=Fmax-P24.15

 

5.00Hz
P24.16 Reset time of dry run protection 0.0~6000.0 240.0s
P23.21 Dry run detection mode

0000:Coast stop

1000:Fast stop

3000:Continue to run

0000

 

3. Water full protection function parameters:

 

P47.18 Full water level detection channel

0:ineffective

1:AI1

2:AI2

3:AI3

4:AI4

Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

0
P47.19 Full water level detection value

0.0~100.0%

 

 

0.0%
P47.20 Full water level detection time

0.0~3000.0s

When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.

 

10.0s
P47.21 Full water recovery time

0.0~3000.0s

When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

10.0s

 


 