logo
Solutions
0+
Countries worldwide
0+
Partners
0+
Patents
0+
Employees
Company events
Over-Excitation Braking or Braking Resistor: Which One Should a VFD Use? Over-Excitation Braking or Braking Resistor: Which One Should a VFD Use? Introduction When a motor-driven machine slows down, its stored mechanical energy does not disappear immediately. The rotating load can drive the motor like a generator and return energy to the VFD DC bus. If that energy accumulates faster than the drive can handle it, the DC-bus voltage rises and the VFD may trip on overvoltage. Over-excitation braking and a braking resistor are two common ways to improve deceleration. They are not equivalent solutions. The correct choice depends on the amount of regenerative energy, stopping time, braking frequency, load direction, and thermal limits of the motor and braking components. Why Does DC-Bus Overvoltage Occur During Deceleration? During normal motoring, electrical energy flows from the supply through the VFD to the motor. During rapid deceleration, a high-inertia load continues rotating and drives the motor. The energy then flows back toward the DC bus. A standard diode-front-end VFD cannot normally return this energy to the power grid, so the DC voltage increases. Extending the deceleration time reduces the rate of regenerated energy and is often the first adjustment to consider. However, some processes require a short stopping time, and some loads regenerate continuously or repeatedly. In those cases, an additional braking method is needed. What Is Over-Excitation Braking? Over-excitation braking increases motor excitation during deceleration so that part of the mechanical energy is converted into heat inside the motor. It can strengthen the braking effect without an external resistor and can be useful for occasional stops or moderate regenerative energy. Its capacity is limited by the motor's thermal condition and by the control strategy of the drive. Repeated or prolonged use can increase motor temperature, and the available braking torque may not be sufficient for a high-inertia machine or a very short deceleration time. Over-excitation braking should therefore not be presented as a universal replacement for a braking resistor. How Does a Braking Resistor Work? A braking transistor or external braking unit monitors the DC-bus voltage and switches regenerated energy into a braking resistor. The resistor converts the electrical energy into heat outside the motor. This provides a defined path for larger or more frequent braking energy and helps prevent DC-bus overvoltage. The resistor must be selected according to the drive specification, minimum permitted resistance, peak braking power, average power, and duty cycle. Some VFD ratings include a braking transistor, while others require an external braking unit. The resistor also needs adequate ventilation and safe clearance because its surface temperature can become very high. When Is Over-Excitation Braking Suitable? Over-excitation braking can be considered when stops are occasional, load inertia is moderate, the deceleration time is not extremely short, and the motor has sufficient thermal margin. Typical examples may include machines that need a firmer stop than a natural coast-down but do not generate large amounts of energy in every cycle. It can also be useful when installation space is limited or an external resistor is undesirable. Even so, the motor temperature and actual stopping performance should be verified during commissioning. If overvoltage trips continue, simply increasing excitation is not a safe substitute for analyzing the braking energy. When Should a Braking Resistor Be Used? A braking resistor is usually the more appropriate choice for repeated rapid stops, large-inertia loads, short cycle times, or overhauling loads that can drive the motor. Examples include centrifuges, high-speed spindles, unwinders, reciprocating machines, and some crane or hoist movements. For lifting applications, the resistor only manages electrical braking energy. It does not hold a suspended load and cannot replace a properly designed mechanical brake or safety system. If the load regenerates continuously or the braking energy is very large, a regenerative drive or active front end may be more suitable than a conventional resistor system. Can Both Methods Be Used Together? Depending on the VFD model and control strategy, over-excitation braking may be used together with a braking resistor. Motor loss can absorb part of the energy, while the resistor handles the energy that raises the DC bus above the braking threshold. This can improve deceleration performance in some applications. However, combined operation does not remove the need to calculate resistor resistance, power, and duty cycle. The final selection should be based on the machine's maximum speed, total inertia, required stopping time, cycle frequency, and potential energy from vertical movement. Common Selection and Installation Mistakes Common mistakes include setting an unrealistically short deceleration time, choosing a resistor only by motor power, using resistance below the drive's permitted minimum, ignoring braking duty, or installing the resistor inside a poorly ventilated control cabinet. Connecting a resistor to a drive that requires an external braking unit is another serious error. Commissioning should include repeated-stop testing under the heaviest expected load. Engineers should monitor DC-bus voltage, motor temperature, resistor temperature, stopping time, and fault history. Protective devices and wiring must follow the VFD and braking component manuals. Choosing a Braking Method for VEIKONG Drives VEIKONG drives provide braking functions according to the selected series and rating. When planning a system, users should confirm whether the drive has an internal braking transistor, requires an external braking unit, and supports the intended control function. The motor, VFD, resistor, and machine duty must be considered as one system. Over-excitation braking is a practical option for moderate and intermittent deceleration, while a correctly sized braking resistor offers greater energy-handling capability for frequent or demanding stops. A clear calculation and real-load test will produce a safer and more reliable result than selecting either method by habit. Related Words: VFD over-excitation braking VFD braking resistor selection DC-bus overvoltage during deceleration
2026-11-24 16:26:19 More >
Why Is Motor Auto-Tuning Important Before Running a VFD? Why Is Motor Auto-Tuning Important Before Running a VFD? Introduction A variable frequency drive can often start a motor after only the basic nameplate data have been entered. However, successful rotation does not necessarily mean that the drive has an accurate model of the motor. For applications that require strong low-speed torque, stable current control, fast response, or precise speed regulation, motor auto-tuning is an important part of commissioning. Auto-tuning allows the VFD to identify electrical characteristics that cannot be fully described by rated voltage, current, frequency, speed, and power alone. With more accurate motor parameters, the drive can calculate the appropriate voltage and current commands more effectively and make vector control perform as intended. What Is Motor Auto-Tuning? Motor auto-tuning, also called motor identification or parameter identification, is a procedure in which the VFD tests the connected motor and calculates parameters for its internal motor model. Depending on the drive, motor type, and selected control mode, these may include stator resistance, leakage inductance, magnetizing characteristics, no-load current, or rotor-related parameters. The exact parameters identified are not identical on every VFD. The important point is that the drive is learning the actual electrical behavior of the connected motor instead of relying only on default values. This is especially relevant in sensorless vector control and closed-loop vector control, where torque-producing current and magnetizing current must be separated and regulated accurately. Why Are Nameplate Parameters Not Always Enough? Two motors with the same rated power can have different winding designs, efficiencies, power factors, current characteristics, and magnetic behavior. Cable length, motor temperature, rewinding history, and the way the motor is connected can also affect the values seen by the drive. Nameplate data provide the essential starting point, but they do not describe every parameter required by a high-performance control algorithm. If the VFD uses an inaccurate motor model, the motor may still run, but its low-speed torque, current stability, speed estimation, and dynamic response may be weaker than expected. Static Auto-Tuning and Rotating Auto-Tuning Static auto-tuning is performed without intentionally rotating the motor shaft. It is useful when the motor cannot be disconnected from the machine or when rotation during commissioning would be unsafe. The VFD applies test signals and identifies the parameters that can be measured while the rotor remains stationary. It is convenient, but the completeness and accuracy of the result depend on the motor and drive design. Rotating auto-tuning allows the motor to turn during identification. It can normally obtain a more complete motor model because the drive can observe the motor under rotation. Before this procedure, the motor should be uncoupled from the load or confirmed to be safely unloaded, and the area must be cleared. Rotating tuning should not be performed casually on hoists, loaded conveyors, pumps with process constraints, or machines whose direction of rotation has not been verified. What Problems Can Incorrect Tuning Cause? Incorrect or missing motor parameters may lead to weak torque at low speed, unstable current, inaccurate speed estimation, slow torque response, increased heating, or unexpected overcurrent trips during acceleration. These symptoms do not always prove that auto-tuning is the only issue, but motor data should be checked early during troubleshooting. A tuning result can also be wrong if the nameplate data were entered incorrectly, the motor was wired in a different star or delta connection from the setting, an output contactor opened during the test, or the motor was already turning. For this reason, preparation is as important as the tuning command itself. A Practical Auto-Tuning Procedure First, confirm the motor type and enter the nameplate voltage, current, frequency, speed, and power accurately. Check the motor wiring and make sure the VFD output is connected directly to the intended motor during identification. Select the correct control mode and the tuning method permitted by the machine. Next, secure the equipment. If rotating tuning is selected, disconnect or safely unload the driven machine, confirm the rotation direction, and keep personnel away. After tuning is completed, save the parameters and test the motor at low speed before increasing the command. Observe current, direction, vibration, noise, and load response. The final test should be performed under real operating conditions. Does Every VFD Application Require Auto-Tuning? Simple fan or pump applications using basic V/F control may operate adequately with correct nameplate data and default motor parameters. In contrast, sensorless vector control, closed-loop vector control, permanent-magnet motor control, high starting torque, and demanding speed-response applications benefit much more from accurate identification. Auto-tuning should therefore be selected according to the control objective rather than treated as an automatic ritual. The commissioning engineer should also follow the drive manual because the permitted tuning method, motor conditions, and safety requirements vary by model. Applying Motor Identification with VEIKONG Drives VEIKONG variable frequency drives provide motor parameter identification functions according to the selected model, motor type, and control mode. Correct nameplate entry, appropriate tuning selection, and a controlled test run help the drive establish a more accurate motor model and deliver the intended control performance. For applications that require strong low-speed torque or faster dynamic response, auto-tuning should be considered part of a complete commissioning process. It does not replace correct sizing, wiring, mechanical inspection, or protection settings, but it gives the VFD a more reliable foundation for controlling the motor.   Related Words: VFD motor auto-tuning Static and rotating auto-tuning Vector control motor parameters
2026-11-24 16:23:18 More >
VEIKONG VFD580 in Brazil Customer Feedback from a Position Controlled Metal Processing Application VEIKONG VFD580 in Brazil Customer Feedback from a Position Controlled Metal Processing Application Real World Feedback from Brazil A drive proves its value not only through laboratory data, but also through the way it performs after it has been integrated into a real machine. VEIKONG recently received installation photos and an operating video from a customer in Brazil showing a VFD580 high-end variable frequency drive applied in a metal processing system with motion and positioning requirements. The field materials show the VFD580 installed inside the machine control cabinet and the production equipment operating on site. The application involves controlled movement of metal sheet through the processing section, where repeatable motion, stable response and coordinated starting and stopping are important to the working cycle. The customer feedback focuses on the VFD580 as a high-end drive for applications that require more than basic speed adjustment. The Control Demands Behind the Application Metal processing equipment often combines rapid acceleration, frequent speed changes, position-related commands and changing mechanical loads. If the drive responds too slowly, produces unstable torque at low speed or cannot coordinate accurately with the control system, the result may be inconsistent movement, longer cycle time or unnecessary mechanical shock. For this type of machine, the drive must provide controlled torque during starting, follow commands quickly and maintain stable motion as the material advances through the equipment. Position feedback and accurate speed regulation can also be important when the machine must repeat a movement or stop at a defined point. The required performance is therefore closer to a motion-control task than to a simple fixed-speed motor application. Why VFD580 Fits a High End Application VFD580 is positioned as VEIKONG’s high-end variable frequency drive for applications with demanding comprehensive performance. It integrates V/F control, sensorless vector control and closed-loop vector control, and supports speed, torque and position operating modes. It can be used with asynchronous motors, synchronous motors and servo motors, giving system designers greater freedom to match the drive to the machine architecture. Under sensorless vector control, the speed regulation range can reach 1:200; with encoder feedback in closed-loop vector control, it can reach 1:1000. The drive also provides strong low-frequency torque and overload capacity, supporting 150% rated output current for 60 seconds, 180% for 10 seconds and 200% for 2 seconds. These characteristics give the system useful control margin during starting, rapid changes in command and short high-load events. Position Feedback and Dynamic Response For equipment that requires more accurate movement, VFD580 can work with multiple encoder technologies through standard or optional interfaces, including incremental HTL or TTL encoders, resolvers, SinCos encoders and selected absolute encoder protocols. This flexibility allows feedback selection to be matched to the motor, control accuracy and system design. The closed-loop vector platform provides the basis for stable low-speed operation, fast current-loop adjustment and accurate response to position or speed commands. Online motor identification helps the drive adapt to changes in key motor parameters, while the integrated speed, torque and position modes reduce the need to combine unrelated control platforms. In a practical machine, these functions help make acceleration, material movement and stopping more controlled and repeatable. Integration and Reliability in the Field The Brazilian installation also demonstrates the practical side of drive selection. VFD580 uses plug-in weak-current terminals to simplify wiring and maintenance, and communication options include Modbus RTU, CANopen, PROFINET and EtherCAT within the relevant product configuration. Its expansion architecture supports encoder, communication and I/O requirements without forcing every application to use the same hardware arrangement. Reliability is supported by an independent air-duct design that helps reduce dust entry into the electronic section, comprehensive current and temperature protection, ground short-circuit protection and motor temperature monitoring options. The series is designed for operation without derating at ambient temperatures up to 50 degrees Celsius when installed under the specified conditions. These details matter in production environments where stable operation and maintainability are as important as control performance. What the Customer Feedback Shows According to the information shared with VEIKONG, the customer regards VFD580 as a high-end drive suitable for positioning-related industrial applications. The installation photo confirms that the unit has been integrated into the control cabinet, while the operating video shows the machine running in the actual Brazilian production environment. Together, these materials provide more meaningful evidence than a general statement of approval: they show the product being selected, installed and used in a working system. This application also illustrates how VEIKONG works with overseas customers. Product capability is only one part of the solution; correct model selection, parameter configuration, system integration and application support are equally important. Feedback from the field helps VEIKONG continue improving products and gives other machine builders a clearer reference for similar motion and positioning requirements. Supporting More Demanding Industrial Projects From metal processing and machine tools to textiles, printing, packaging, lifting and other automation equipment, VFD580 is designed for projects that require strong vector control, broad motor adaptability and flexible system expansion. The Brazilian customer application confirms the role of VFD580 as more than a general speed controller: it is a high-performance drive platform for machines where dynamic response, feedback control and reliable operation directly affect the process. VEIKONG will continue working with customers and partners in Brazil and other international markets to provide drive products, technical support and application solutions for demanding industrial equipment. Related Words: VFD580 positioning control Brazil industrial drive application high-end vector drive
2026-11-03 11:53:28 More >
From Proven Performance to Greater Possibilities: VEIKONG Launches VFD500Plus From Proven Performance to Greater Possibilities: VEIKONG Launches VFD500Plus A Proven Platform Continues to Evolve VEIKONG is pleased to introduce VFD500Plus, the next evolution of the proven VFD500 high-performance vector drive platform. For many years, VFD500 has served customers across a wide range of industrial applications and has built a strong reputation for stable operation, practical functions and reliable motor control. It has been one of VEIKONG's important general-purpose drive products and a dependable choice for machine builders, system integrators and end users. VFD500Plus builds on that established foundation. The “Plus” designation represents continuity as well as progress: the new series retains the practical general-purpose positioning of VFD500 while expanding motor compatibility, control performance, functional safety, communication options and system scalability. It is designed for customers who value the proven strengths of VFD500 but need additional capabilities for newer machines and more connected industrial systems.For users and service teams already familiar with VFD500, this development path also creates a clear product logic. Existing VFD500 experience remains valuable, while VFD500Plus provides a higher-specification option when new projects introduce more demanding motion control, safety integration or network requirements. Customers can therefore select the appropriate platform according to actual application needs rather than treating every project as requiring the same drive configuration. Broader Motor Compatibility VFD500 has provided mature control for asynchronous motor applications in many industries. VFD500Plus extends this capability to a wider range of motor technologies. In addition to asynchronous motors, it supports surface-mounted permanent magnet synchronous motors, interior permanent magnet synchronous motors and synchronous reluctance motors. This broader compatibility allows equipment manufacturers to use one drive platform across more machine designs. Whether a project focuses on traditional induction motors, higher-efficiency permanent magnet motors or newer synchronous reluctance solutions, VFD500Plus provides greater flexibility for product development, upgrading and standardization. Enhanced Vector Control and Low Speed Performance Building on the V/F and sensorless vector control experience of VFD500, VFD500Plus provides V/F control, sensorless vector control and closed-loop vector control with a speed sensor. Its speed regulation range reaches 1:100 under V/F control, 1:200 under sensorless vector control and 1:1000 under closed-loop vector control. The drive also delivers strong low-speed load capability: 150% at 0.5 Hz in V/F mode, 180% at 0.25 Hz in sensorless vector mode and 180% at zero speed in closed-loop vector mode. These improvements give users more control headroom in applications requiring stable starting, accurate speed regulation, rapid load response or dependable torque at very low speed. A Wider Power Range and Stronger System Scalability VFD500Plus covers power ratings from 0.4 kW to 1000 kW, allowing the same product family to support compact machinery as well as large industrial systems. The expanded range helps customers reduce the need to combine unrelated drive platforms when equipment portfolios include both low-power and high-power machines. Two motor parameter groups, multiple acceleration and deceleration settings, process PID, simple PLC logic, multi-step speed operation, skip frequency and V/F separation further improve adaptability. These functions support different operating conditions without losing the straightforward commissioning approach expected from a general-purpose drive. Functional Safety and Reliability Upgrades Dual Safe Torque Off inputs are standard on VFD500Plus. In an appropriately designed safety system, STO can prevent the drive from producing motor torque and gives machine designers a more convenient basis for integrating functional safety. The final safety architecture should always be evaluated according to the machine, risk assessment and applicable standards. Reliability has also been further strengthened through thermal simulation, optimized heat dissipation and an independent air duct that helps reduce dust entry into the drive. A large-air-volume, long-life cooling fan and enlarged aluminum heat-sink fins support temperature control. Comprehensive protection functions cover conditions including phase loss, overcurrent, motor overload, drive overload, overtemperature, ground short circuit, motor overspeed, speed deviation and PID feedback loss. More Communication and Expansion Choices VFD500Plus retains standard Modbus communication and adds a broader range of optional network solutions, including CANopen, EtherCAT, PROFINET, Modbus TCP, Ethernet and BACnet. This makes the drive easier to integrate into PLC systems, industrial Ethernet networks, building automation and more advanced machine architectures. Encoder expansion options include incremental encoders, resolvers and Tamagawa-protocol absolute encoders. Users can also select a standard digital keypad, an optional dual-display keypad or an optional LCD keypad. Together with expandable I/O and communication options, these choices make configuration more flexible while keeping the standard product practical. Smooth Operation for Modern Industrial Applications Speed tracking start allows VFD500Plus to identify and smoothly restart a motor that is still rotating, helping reduce current and mechanical shock on fans, pumps and other inertia loads. Over-excitation can assist deceleration in suitable applications, while under-voltage stall prevention helps the motor decelerate in a controlled manner during a momentary power interruption and supports recovery after power returns. VFD500 remains a proven high-performance platform whose reliability has been demonstrated through years of industrial use. VFD500Plus carries that experience forward and adds more capability for projects that require multiple motor types, higher control accuracy, functional safety, broader connectivity or a larger power range. With this launch, VEIKONG offers customers a stronger and more future-ready general-purpose drive platform without losing the practical engineering foundation that made VFD500 successful. Related Words: VFD500Plus upgrade  VFD500 vector drive High performance industrial drive
2026-11-02 17:20:26 More >
Welcome to send the inquiry
Please communicate your requirements for products through the online communication form we will reply with faster quatiation in Email and mobile
We keep working online, get in touch.
+86 139 2373 6332 (WhatsApp)
Terry.lee@veikong.com
4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China